Uni-Tube Single Mode Fiber Optic Cable

AED 0.00
In stock
Product Model
GYXTW
Uni-Tube Single Mode Fiber Optic Cable is a compact outdoor optical cable designed for telecom, data communication, and network infrastructure applications. Featuring a PBT loose tube construction, galvanized steel strength members, and robust environmental protection, it delivers reliable long-distance optical transmission and mechanical durability. Suitable for aerial and duct installations, the cable is designed to perform in demanding outdoor environments while maintaining stable signal quality.

Key Features:

1) Single-mode fiber optic cable

2) Supports 2 to 12 fiber cores

3) Uni-tube loose tube construction

4) PBT loose tube for fiber protection

5) Dual galvanized steel strength members

6) Compact and lightweight cable design

7) Excellent tensile strength performance

8) High crush resistance up to 1000N/10cm

9) Suitable for outdoor telecom applications

10) Ideal for aerial and duct installations

11) Reliable long-distance optical transmission

12) Operating temperature range from -40°C to +60°C

13) Flexible installation with excellent bending performance

14) Durable design for harsh environmental conditions

15) Suitable for ISP, telecom, enterprise, and network infrastructure projects

16) Low maintenance and long service life for outdoor deployments

More Information
Technical specification
Structure Unit GYXTW-XX
Fiber count Fibers 2 to 12
Loose tube Material   PBT
Loose tube Diameter Diameter Ф2.5mm
Strength Member Material   GI Steel
Strength Member Material Diameter 2 * Ф0.8mm
Increase Strength Material   -
Increase Strength Diameter Diameter -
Steel Wire Diameter 2 * Ф0.8mm
Outer Sheath Material HDPE
Outer Sheath (Tnhoicmkinneals*s) -
Cable diameter (nominal**) mm 7.5
Cable Weight (Approx.) Kg/km 62
Bending Radius Dynamic - ≥20D
Bending Radius Static - ≥10D
Operation temperature range °C -40 ~ +60
Installation temperature range °C -20 ~ +50
Transport and storage
temperature range
°C -40 ~ +60
Max. tensile load N 1000
Crush resistance N 1000/10cm
 
Note 1: Tensile strength and crush resistance shall vary as per the cable diameters, steel rod diameter and thickness of sheath.
 
Parameter Unit 9/125SMF-OS2 62.5/125MMF-OM1 50/125MMF-OM2 50/125MMF-OM3 50/125MMF-OM4
Attenuation (See Note 1) dB/Km 1310nm≤0.35
1550nm≤0.22
850 nm≤3.0
1300 nm≤0.8
850 nm≤3.0
1300 nm≤0.7
850 nm≤2.3
1300 nm≤0.7
850 nm≤2.3
1300 nm≤0.7
Dispersion Ps/nm.km 1285~1330nm≤3.51550nm≤18.0
Fiber diameter um 9/125 um 62.5/125 um 50/125 um 50/125 um 50/125 um
Effective Modal Bandwidth EMB   850 nm≥200 850 nm≥750 850 nm≥2000 850 nm≥4700
Zero dispersion wavelength Nm 1300~1324
Zero dispersion Slope Ps/nm.km ≤0.095
Fiber cutoff wavelength um ≤1260
Mode field diameter um @1310nm-9.2±0.4
@1550nm-10.4±0.8
Mode field concentricity um ≤0.8
Cladding diameter um 125±1.0 125±2.0 125±1.0 125±1.0 125±1.0
Cladding non-circularity % ≤1.0 ≤2.0 ≤1.0 ≤1.0 ≤1.0
Coating/cladding concentricity error um ≤12.5 ≤12.5 ≤12.5 ≤12.5 ≤12.5
Coating diameter um 245±10 245±10 245±10 245±10 245±10
 
Note 1:Fiber attenuation for tight buffer cables is a little higher than bare fibers.
Note 2:For more detailed specifications on Fiber Core Characteristics, please write to us at asteldigicom@eim.ae or visit the fiber core manufacturer’s website.

Item Test Method Acceptance Requirements
Tension Loading Test IEC 60794-1-2-E1 Sample length: No less than 50 meters
Loading: 1000N
Duration time: 10 minutes
Loss change ≤ 0.1dB @1550nmFiber strain at max. load: max.0.33%No fiber break and no sheath damage.
Crush Test IEC 60794-1-2-E3 Sample length: No less than 50 meters
Loading: 1000N
Duration time: 10 minutes
Loss change ≤ 0.1dB @1550 nmNo fiber break and no sheath damage
 Impact Test IEC 60794-1-E4 Loading: 1KG,1m
Radius of hammer head: 12.5mm
Sample length: 5m
Duration time: 2 sec/cycle
No of cycles: 5 cycles
Points of impact: 5 points
 Loss change ≤ 0.1 dB @1550 nm
No fiber break and no sheath damage.
Repeated Bending IEC 60794-1-E6 Bending Radius.: 20 x cable diameter
Load: 150N
Flexing rate: 3sec/cycle
No. of cycle: 30
Loss change ≤ 0.1 dB @1550 nm
No fiber break and no sheath damage.
Torsion/Twist Test IEC 60794-1-E7 Length: 2m
Load: 150N
Twist rate: 1min/cycle
Twist angle: ±180°
No. of cycle: 10
Loss change ≤ 0.1 dB @1550 nm. No fiber break and no sheath damage.
Water Penetration IEC 60794-1-2-F5 Height of water: 1m
Sample length: 3 m
Time: 24 hours
No water leakage at the end of the sample
Temperature Cycling IEC 60794-1-2-F1 Temperature step:
+20ºC→-40ºC→+60ºC→-40ºC→+60ºC→+20ºC
Number of cycles: 2
Time each step: 12 hours
Loss change ≤ 0.1 dB @1550 nm. No fiber break and no sheath damage.
Bending Test IEC 60794-1-2-E11B Bending Dia: 20 x cable diameter
No. of cycle: 5
Loss change ≤ 0.1dB @1550nmNo fiber break and no sheath damage
IDEriCp 6T0e7s9t4-1-2-E14 Length: 0.3m
Temperature: +70ºC
Duration of Test: 24 hrs
No filling compound shall drip from tubes
 
Disclaimer
1. Astel Digicom Electronics reserves the right to change or modify specifications without prior notice.
2. All pictures are for illustrative purposes only. Actual product may be different in color and size from what appears in product specifications.
3. Every effort is made to provide accurate information at the time of publishing. Astel Digicom Electronics LLC is not responsible for any loss, directly or indirectly, caused by any error in publishing. 
4. E&OE (Errors and Omissions are excepted)