ASTEL LC Series Fiber Optic Patch Cord – Single Mode and Multimode

AED 0.00
In stock
Product Model
FO-PC-LC-XX

ASTEL LC Series Fiber Optic Patch Cord (FO-PC-LC-XX) is designed for optical connectivity in fiber networks, data centres and professional communication infrastructure. Featuring LC connector options and Low Smoke Zero Halogen (LSZH) jacketed cable, the series supports single-mode and multimode fiber installations.
Available in LC/PC, LC/UPC and LC/APC configurations, the series supports OS2 (G.652D), G.657A2 and multimode OM1, OM2, OM3 and OM4 fiber types. The patch cords offer typical insertion loss of ≤0.20dB, maximum insertion loss of ≤0.30dB and return loss ratings according to connector polish type.
Standard lengths range from 0.5m to 100m, with custom lengths from 0.3m to 250m available on request. ASTEL LC patch cords are manufactured and tested for optical loss, connection integrity and connector geometry to support professional fiber optic installations.

Key Features

  • Product model: FO-PC-LC-XX

  • Product series: ASTEL LC Fiber Optic Patch Cord

  • Connector options: LC/PC, LC/UPC and LC/APC

  • Single-mode fiber types: OS2 (G.652D) and G.657A2

  • Multimode fiber types: OM1, OM2, OM3 and OM4

  • Single-mode fiber diameter: 9/125µm

  • OM1 multimode fiber diameter: 62.5/125µm

  • OM2, OM3 and OM4 multimode fiber diameter: 50/125µm

  • LSZH (Low Smoke Zero Halogen) cable jacket

  • Typical insertion loss: ≤0.20dB

  • Maximum insertion loss: ≤0.30dB

  • Return loss for single-mode LC/PC and LC/UPC: ≥55dB

  • Return loss for single-mode LC/APC: ≥60dB

  • Return loss for multimode LC/PC: ≥35dB

  • Insertion and withdrawal cycles: Greater than 1,000

  • Change in insertion loss after 1,000 mating cycles: ≤0.20dB

  • Radius of curvature (ROC): 10–25mm

  • Apex offset: ≤50µm

  • Fiber height: -50nm to +50nm

  • Operating temperature: -40°C to +75°C

  • Storage temperature: -40°C to +85°C

  • Telcordia compliance listed in technical specifications

  • Manufactured in an ISO 9002-approved plant, as stated by ASTEL

  • Tested for insertion loss, return loss, connection integrity and 3D connector geometry

  • Suitable for direct deployment in fiber networks and data centres without additional protection tubes

  • Standard and custom cable lengths available

More Information
Technical specification
Parameter Single-mode PC/UPC Single-mode APC Multimode PC
Connector LC/PC, LC/UPC LC/APC LC/PC
Fiber type OS2 (G652D), G657A2 OS2 (G652D), G657A2 OM1, OM2, OM3, OM4
Standard Lengths 0.5m, 1m, 3m, 5m, 10m, 15m, 25m, 30m, 50m 60m, 70m, 100m
Custom Length  Any length from 0.3m to 250m can be provided on request 
Mechanical Specifications:
Insert and pull frequency  >1000 
Changeability  ≤ 0.20 
Tensile strength  < 0.1 
Oscillating test  < 0.1 
Electrical Specifications    
Typical Insertion Loss (dB)  ≤0.20 
Max Insertion Loss (dB)  ≤0.30 
Change in loss(dB)
After 1000 matings
 ≤0.20 
Return loss (dB) ≥55 ≥60 ≥35
ROC  10- 25 mm 
Apex Offset  ≤50 um 
Fiber Height  -50 nm to +50 nm 
Compliance Standard  Telecordia 
Operating temperature  -40 ±75 centigrade 
Storage temperature  -40 ±85 centigrade 
 
Parameter Unit 9/125SMF-OS2 62.5/125MMF-OM1 50/125MMF-OM2 50/125MMF-OM3 50/125MMF-OM4
Attenuation (See Note 1) dB/Km 1310nm≤0.351550nm≤0.22 850 nm≤3.01300 nm≤0.8 850 nm≤3.01300 nm≤0.7 850 nm≤2.31300 nm≤0.7 850 nm≤2.31300 nm≤0.7
Dispersion Ps/nm.km 1285~1330nm≤3.51550nm≤18.0 _ _ _ _
Fiber diameter um 9/125 um 62.5/125 um 50/125 um 50/125 um 50/125 um
Effective Modal Bandwidth EMB   850 nm≥200 850 nm≥750 850 nm≥2000 850 nm≥4700
Zero dispersion wavelength Nm 1300~1324 _ _ _ _
ZTeercoh ndiicsapl erSspioecni fsilcoaptieons Ps/nm.km ≤0.095 _ _ _ _
Fiber cutoff wavelength um ≤1260 _ _ _ _
Mode field diameter um @@11535100nnmm--190..24±±00..48 _ _ _ _
Mode field concentricity um ≤0.8 _ _ _ _
Cladding diameter um 125±1.0 125±2.0 125±1.0 125±1.0 125±1.0
Cladding non-circularity % ≤1.0 ≤2.0 ≤1.0 ≤1.0 ≤1.0
cCoonactienngt/riccliatdy deirnrgor um ≤12.5 ≤12.5 ≤12.5 ≤12.5 ≤12.5
Coating diameter um 245±10 245±10 245±10 245±10 245±10
 
Note 1: Fiber attenuation for tight buffer cables is little higher than bare fibers.
Note 2: For more detailed specification on Fiber Core Characteristics, please write to us at asteldigicom@eim.ae or visit fiber core manufacturer’s website.
Disclaimer
1. Astel Digicom Electronics reserves the right to change, modify specifications without prior notice.
2. All pictures are for illustrative purposes only. Actual product may be different in color and size that may appear in product specifications.
3. Every effort is made to provide accurate information at the time of publishing, however Astel Digicom Electronics LLC is not responsible for any loss, directly or indirectly caused by any error in publishing.
4. E&OE (Errors and Omissions are excepted)