Industrial Power Supply DIN Rail Mount IMC-PSU-48V-10A

AED575.00
In stock
Product Model
AST-IMC-PSU-48V-10A (DR-480-48)
PRODUCT DESCRIPTION:
AST-IMC-PSU-48-10A (DR-480-48) are a reliable solution for Industrial Media Converters that
run on a +48 VDC power input. It can operate reliably in temperatures ranging from -20°C
to 70°C. It is feature rich and has built in over voltage, over current, short circuit and over
temperature protection.
 
Main Features:
1) Industrial Grade Power supply
2) DIN Rail mountable TS-35/7.5 or 15
3) AC input range 90VAC-264VAC
4) SMPS type, High Efficiency
5) Protections: Short Circuit / Overload / Over Voltage / Over Temperature
6) LED Indicator for Power on
7) 100% Full load burn in test
8) 1 year warranty
9) Cooling by free air convection
More Information
Technical specification
Specification:
Product Name AST-IMC-PSU-48V-10A (DR-480-48)
OUTPUT  
DC Voltage 48V
Rated Current 10.0A
Current Range 10.0A
Rated Power 480W
Ripple & Noise (max.) Note.2

≤50mVp-p @ 0°C ≤Ta≤55°C

≤100mVp-p @ -15°C ≤Ta≤0°C

Voltage Precision ± 1.0%
Voltage Tolerance Note.3 ±1.0%
Line Regulation ±1.0%
Load Regulation ±2.0%
Output Start Time   ≤2.0s/220VAC at Full Load / ≤3.0s/110VAC at full load
Hold Up Time (Typ.) 20ms/220VAC / 10ms/110VAC at full load
INPUT  
Voltage Range 90 - 264VAC
Frequency Range 47 - 63Hz
Efficiency (Typ.) 93.5%
AC Current (Typ.) 6.0A/220VAC
Inrush Current (Typ.) COLD START 40A /230VAC
Leakage Current <0.25mA / 220VAC
PROTECTION  
Overload 120 -150% rated output powerProtection type : Constant current limiting, recover sautomatically after fault condition is removed
Over Voltage 58 - 60V Protection type : Shut down o/p voltage, re-power on to recover
Over Temperature 75°C ±5°CProtection type : Shut down o/p voltage, recovers automatically
after temperature goes down
ENVIRONMENT  
Working Temp -40 - +70°C (Refer to “Derating Curve”)
Working Humidity 20 - 90% RH non-condensing
Storage Temp., Humidity -40 - +85°C, 10 - 95% RH
Temp. Coefficient ±0.03%rc (0 - 50°C)
Vibration 10 - 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes;Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)  
Safety Standards GB4943 / TUV EN60950
Withstand Voltage I/P-O/P- 3KVAC/10mA, I/P-F/G: 1.5KVAC-10mA, O/P-FG:1.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, 0/P-FG:100M Ohms / 500VDC / 25°C/
EMC Emission Compliance to EN55022 (CISPR22) Class B,
EMC Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11, ENV55024, 

heavy industry level,

Harmonic Current

IEC 61000-3-2 Class A equipment requirements

Others  
MTBF 100, 000 hrs min. MIL-HDBK-217F-2
Dimension 138.5*136.5*70mm (W*H*D)
Net weight/ Gross weight 1.75Kg/2.50 Kg
 
*Notes:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of
ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with
a 0 luf & 47uf parallel capacitor
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment.