GYFXTCY-ADSS Optical Fiber Cable 4F to 24F Uni Tube All Dielectric Non Metal Armor

In stock
SKU
GYFXTCY
Main Features:
 
1) All Dielectric Self Support Fiber Optic Cables
2) Non Metal Armor.
3) GYFXTCY model features good ability to shield from electromagnetism induced voltages or currents.
4) Suitable for Outdoor installation alongside MV/HV Electrical Transmission lines.
5) Long Distance fiber signals transmission for Cable TV, IP, Telecommunication, Security
6) Excellent AT performance. The maximum inductive at the operating point o AT Sheath can reach 25KV.
 
AED0.00

Details

Product Applications
 
1) All Dielectric Self Support Fiber Optic Cables
2) Non Metal Armor.
3) GYFXTCY model features good ability to shield from electromagnetism induced voltages or currents.
4) Suitable for Outdoor installation alongside MV/HV Electrical Transmission lines.
5) Long Distance fiber signals transmission for Cable TV, IP, Telecommunication, Security
6) Excellent AT performance. The Maximum inductive at the operatinig point of AT sheath can reach 25KV.
7) Large span lengths at the largest span is over 1000m
8) Good performance of tensile strength and temperature withstand capablity.
9) Suitable for Middle east in high ambient temperature

More Information

Technical specification

<address> </address><address><span style="font-size: small;"><strong><span style="font-family: verdana, geneva;">GYFXTCY:4F to 24F (Uni Tube Model, Dual Sheath)</span></strong></span></address><address> </address><address><span style="font-size: small;"><strong><span style="font-family: verdana, geneva;">Product Constructions details:</span></strong></span></address><address> <br /><span style="font-family: verdana,geneva; font-size: small;">1) Loose Tube is made up of PBT (High Modulus Plastic) which has high capacity to withstand wide temperature fluctuations.</span><br /><span style="font-family: verdana,geneva; font-size: small;">2) The tube is filled with Moisture Resistance GEL to prevent longitudinal moisture ingress.</span><br /><span style="font-family: verdana,geneva; font-size: small;">3) The tube is covered togethers with cloth binder.</span></address><address><span style="font-family: verdana,geneva; font-size: small;">7) After the cloth binder, a thin inner sheath is extruded.</span><br /><span style="font-family: verdana,geneva; font-size: small;">8) After the inner sheath there is Aramid yarn (Dielectric Armor)- which provides crush resistance and tensile strength to the cable.</span></address><address><span style="font-family: verdana,geneva; font-size: small;">9) After the dielectric armor- outer HDPE sheath is extruded. It also adds to the crush resistance and tensile strength of the cable. High quality HDPE provides good ultravoilet radiation property. Outer sheath can be PE or AT (Anti Tracking) sheath.</span></address><address> </address><address><span style="font-family: verdana,geneva; font-size: small;">For more detailed specs- please download the technical specs sheet.</span></address><address> </address><address><span style="font-size: small;"><strong><span style="font-family: verdana, geneva;">Fiber Core Specifications:</span></strong></span></address><address>  </address><address> <table class="table table-striped table-bordered" style="width: 600px; border: 1px solid #afcbe4;" border="1"> <tbody> <tr> <td><strong><span style="font-family: verdana, geneva; font-size: small;">Parameter</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">Unit</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">9/125SMF-OS2</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">62.5/125MMF-OM1</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">50/125MMF-OM2</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">50/125MMF-OM3</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">50/125MMF-OM4</span></strong></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Attenuation (See Note 1)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">dB/Km</span></td> <td style="text-align: center;"> <p><span style="font-family: verdana, geneva; font-size: small;">1310nm≤0.35</span></p> <p><span style="font-family: verdana, geneva; font-size: small;">1550nm≤0.22</span></p> </td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≤3.01300 nm≤0.8</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≤3.01300 nm≤0.7</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≤2.31300 nm≤0.7</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≤2.31300 nm≤0.7</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Dispersion</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Ps/nm.km</span></td> <td style="text-align: center;"> <p><span style="font-family: verdana, geneva; font-size: small;">1285~1330nm≤3.5</span></p> <p><span style="font-family: verdana, geneva; font-size: small;">1550nm≤18.0</span></p> </td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber diameter</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">9/125 um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">62.5/125 um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">50/125 um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">50/125 um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">50/125 um</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Effective Modal Bandwidth</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">EMB</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≥200</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≥750</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≥2000</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">850 nm≥4700</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Zero dispersion wavelength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">1300~1324</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">ZTeercoh ndiicsapl erSspioecni fsilcoaptieons</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Ps/nm.km</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤0.095</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber cutoff wavelength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1260</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Mode field concentricity</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤0.8</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">_</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Cladding diameter</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">125±1.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">125±2.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">125±1.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">125±1.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">125±1.0</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Cladding non-circularity</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">%</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤2.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1.0</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Coonactienngt/riccliatdy deirnrgor</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤12.5</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤12.5</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤12.5</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤12.5</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤12.5</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Coating diameter</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">um</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">245±10</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">245±10</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">245±10</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">245±10</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">245±10</span></td> </tr> </tbody> </table> </address><address> </address><address><span style="font-family: verdana, geneva; font-size: small;"><span style="font-size: x-small;"><span style="color: #ff0000;">Note 1:</span> <span style="font-family: verdana,geneva;">Fiber attenuation for tight buffer cables is little higher than bare fibers.</span></span><br /><span style="font-size: x-small;"><span style="color: #ff0000;">Note 2:</span> <span style="font-family: verdana,geneva;">For more detailed specification on Fiber Core Characteristics, please write to us at asteldigicom@eim.ae or visit fiber core manufacturer’s website.</span></span><br /><br /><br /></span></address><address><span style="font-family: verdana,geneva; font-size: x-small; color: #000000;"><span style="color: #ff0000;">Disclaimer</span><br />1. Astel Digicom Electronics reserves the right to change, modify specifications without prior notice.<br />2. All pictures are for illustrative purposes only. Actual product may be different in color and size that may appear in product specifications.<br />3. Every effort is made to provide accurate information at the time of publishing, however Astel Digicom Electronics LLC is not responsible for any loss, directly or indirectly caused by any error in publishing.<br />4. E&OE (Errors and Omissions are excepted)</span></address><address><span style="font-family: verdana, geneva; font-size: small;"> </span></address>

Subscription