Fiber Optic Patch Cord Bend Insenstitive Series G657A1 / G657A2

In stock
SKU
G657A1 / G657A2
ASTEL Fiber patch Cords employ highest grade components, manufacturing processes and test methods that offer excellent performance for demanding telecommunications and data applications.
AED0.00

Details

1) ASTEL Fiber patch Cords employ highest grade components, manufacturing processes and test methods that offer excellent performance for demanding telecommunications and data applications.
2) ASTEL FO Patch cord with BEND INSENSITIVE FIBER(G657A1 and G657A2) can be directly deployed in FTTH Networks and Data Centres, where space is very big constraint and Patch cords may be subjected to Micro bending Loss.
3) ASTEL FO patch cords are manufactured in ISO 9002 approved plant and tested for Forward loss, Return loss Connection integrity and 3D spectrum tester for performance and quality.
4) ASTEL FO patch cords use LSZH Jacket cables (Low Smoke Zero Halogen).

More Information

Technical specification

<address> <table class="table table-striped table-bordered" style="border-color: #afcbe4; border-width: 1px; width: 600px; border-style: solid;" border="1"> <tbody> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Parameter</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Single mode PC/UPC</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Single mode APC</span></strong></span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Connector</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">SC/LC/FC/ST/E2000</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber type</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">G657A1 and G657A2</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Standard Lengths</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">0.5m, 1m, 3m, 5m, 10m, 15m, 25m, 30m, 50m 60m, 70m, 100m</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Custom Length</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">Any length from 0.3m to 250m can be provided on request</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Mechanical Specifications:</span></strong></span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;"> </span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Insert and pull frequency</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">>1000</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Changeability</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.20</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Tensile strength</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">< 0.1</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Oscillating test</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">< 0.1</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Electrical Specifications</span></strong></span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;"> </span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Typical Insertion Loss (dB)</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">≤0.20</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Max Insertion loss (dB)</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">≤0.30</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Change in loss(dB)</span><br /><span style="font-family: verdana, geneva; font-size: small;">After 1000 mating</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">≤0.20</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Return loss (dB)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≥55</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≥60</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">ROC</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">10-25mm</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Apex Offset</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">≤50 um</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber Height</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">-50 nm to +50 nm</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Compliance Standard</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">Telecordia</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Operating temperature</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">-40 ±75 centigrade</span><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Storage temperature</span></td> <td style="text-align: center;" colspan="2"><span style="font-family: verdana, geneva; font-size: small;">-40 ±85 centigrade</span></td> </tr> </tbody> </table> </address><address><span style="font-family: verdana, geneva;"> </span></address><address> <table class="table table-striped table-bordered" style="border-color: #afcbe4; border-width: 1px; width: 600px; border-style: solid;" border="1"> <tbody> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Parameter</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">G657A2</span></strong></span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Type of fiber</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Single mode</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber Material</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Doped silica</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Fiber Transmission Characteristics</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Attenuation coefficient</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.35 dB/km</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">@ 1310 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.31dB/km</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">@ 1383 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.21 dB/km</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">@ 1550 nm@ 1625 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.24 dB/km</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">1550nm Macrobending loss(10cycle@ф30mm)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.20 dB</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">1625nm Macrobending loss(10cycle@ф30mm)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.28 dB</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">1550nm Macrobending loss(1cycle@ф20mm)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤0.75 dB</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">1625nm Macrobending loss(1cycle@ф20mm)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1.5 dB</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Zero-dispersion wavelength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">1302 ~ 1322 nm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Zero-dispersion slope</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.091 ps/(nm2.km)</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Chromatic dispersion</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">@ 1288 ~ 1339 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤3.5 ps/(nm. km)</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤5.3 ps/(nm. km)</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">@ 1271 ~ 1360 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤17.5 ps/(nm. km)</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">@ 1550 nm@ 1625 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤22 ps/(nm. km)</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber PMD</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤0.15 ps/km1/2</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">(PMDQ,m=20,Q=0.01%) Fiber PMD link value</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤0.08 ps/km1/2</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Mode field diameter@ 1310 nm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">9.0±0.4 um</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber cut-off wavelength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">1150~1330nm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Cable cut-off wavelength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤1260 nm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Fiber geometry characteristics</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Cladding diameter</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">125.0 ± 0.7 um</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Core / Cladding concentricity error</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.5 um</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Cladding non-circularity</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 1.0%</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Primary coating diameter</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">244 ± 4um</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Cladding non-circularity</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤3.0%</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Coating/Cladding concentricity error</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤10</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Fiber Mechanical Characteristics</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber prooftest levels</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≥ 1.02%</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber strip force peak value</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">1.3~8.9N</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber weibuil 15% strength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≥ 3050 Mpa</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Fiber weibuil 50% strength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≥ 4000 Mpa</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva;"><strong><span style="font-size: small;">Fiber environmental characteristics</span></strong></span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Temperature dependence of attenuation at</span><br /><span style="font-family: verdana, geneva; font-size: small;">1310nm and 1550nm between -60oCand 85oC</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.03dB/km</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Temperature humidity aging attenuation at</span><br /><span style="font-family: verdana, geneva; font-size: small;">1310nm and 1550nm 85oC and 85%RH</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">≤ 0.03dB/km</span></td> </tr> </tbody> </table> </address><address><span style="font-family: verdana, geneva;"> </span></address><address> </address><address><span style="font-family: verdana,geneva; font-size: x-small; color: #ff0000;">Disclaimer </span></address><address><span style="font-family: verdana,geneva; font-size: x-small;">1. Astel Digicom Electronics reserves the right to change, modify specifications without prior notice. </span></address><address><span style="font-family: verdana,geneva; font-size: x-small;">2. All pictures are for illustrative purposes only. Actual product may be different in color and size that may appear in product specifications. </span></address><address><span style="font-family: verdana,geneva; font-size: x-small;">3. Every effort is made to provide accurate information at the time of publishing, however Astel Digicom Electronics LLC is not responsible for any loss, directly or indirectly caused by any error in publishing. </span></address><address><span style="font-family: verdana,geneva; font-size: x-small;">4. E&OE (Errors and Omissions are excepted)</span></address>

Subscription