Technical specification
<address><strong><span style="font-family: verdana,geneva; font-size: small;">Main Applications</span></strong></address><address> </address><address><span style="font-family: verdana,geneva; font-size: small;">1) Paging Systems</span><br /><span style="font-family: verdana,geneva; font-size: small;">2) Conference Systems</span><br /><span style="font-family: verdana,geneva; font-size: small;">3) Stage Programs</span><br /><span style="font-family: verdana,geneva; font-size: small;">4) School auditoriums</span><br /><span style="font-family: verdana,geneva; font-size: small;">5) Karoake Systems</span></address><address> </address><address> <table border="1"> <tbody> <tr> <td><strong><span style="font-family: verdana, geneva; font-size: small;">Model Product </span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">MCS-2C-24AWG</span></strong></td> <td style="text-align: center;"><strong><span style="font-family: verdana, geneva; font-size: small;">MCS-2C-22 AWG</span></strong></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Conductor 1&2</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Stranded OFC Copper</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">Stranded OFC Copper</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Conductor Structure</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">14x0.14 mm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">30x 0.12mm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Conductor Cross Section </span><span style="font-family: verdana, geneva; font-size: small;">Area</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">0.22 mm2</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">0.34 mm2</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Conductor AWG</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">24 AWG</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">22 AWG</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Insulation</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">PE</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">PE</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Insulation thickness</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">1.50 mm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">1.50 mm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Spiral Copper Shielding</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">62x0.11 mm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">62x0.11 mm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Jacket Type and Color</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">PVC, Blue</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">PVC, Black</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Jacket Diameter</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">6.0mm</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">6.0mm</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Rip Cord</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">YES</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">YES</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Dielectric Strength</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">500V/5m</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">500V/5m</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Nominal DCR </span><span style="font-family: verdana, geneva; font-size: small;">for BC (Ohms/Km)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">81.46</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">52.35</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Nominal DCR </span><span style="font-family: verdana, geneva; font-size: small;">for Shielding (Ohms/km)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">34.75</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">34.75</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Capacitance Conductor </span><span style="font-family: verdana, geneva; font-size: small;">to Conductor (pf/M)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">49.73</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">67.37</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Capacitance Conductor to </span><span style="font-family: verdana, geneva; font-size: small;">Shielding (Pf/M)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">101.76</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">113.52</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Tensile Strength of </span><span style="font-family: verdana, geneva; font-size: small;">Jacket (Mpa)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">>8.0</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">>8.0</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Elongation (%)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">>200 %</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">>200 %</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Length each coil</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">100Y (91.2mts)</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">100Y (91.2mts)</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Weight each coil 100Y</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">4.0 Kg</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">4.1 Kg</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Number of </span><span style="font-family: verdana, geneva; font-size: small;">coils in 1 carton</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">4</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">4</span></td> </tr> <tr> <td><span style="font-family: verdana, geneva; font-size: small;">Weight of each </span><span style="font-family: verdana, geneva; font-size: small;">carton</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">17.40 kgs</span></td> <td style="text-align: center;"><span style="font-family: verdana, geneva; font-size: small;">18.60 kgs</span></td> </tr> </tbody> </table> </address><address> </address><address> </address><address> </address><address><span style="font-family: verdana,geneva; font-size: x-small; color: #ff0000;">Notes:</span><br /><span style="font-family: verdana,geneva; font-size: x-small;">* DC resistance changes at the rate of 0.393% / Deg C.</span><br /><span style="font-family: verdana,geneva; font-size: x-small;">* Sequential meter marking on all cables.</span><br /><span style="font-family: verdana,geneva; font-size: x-small;">* Higher core sizes cables also available.</span><br /><span style="font-family: verdana,geneva; font-size: x-small;">* All measurements adjusted for ambient Temp of 20 deg C</span></address>