FLAT TRAVELLING CABLE DUAL SHIELDED DUAL JACKET SFTP CAT6 BC

In stock
SKU
FTCSFTPCAT6BC
ASTEL Flat Travelling Cables are designed and manufactured to Ultra flexibility demand of CCTV Cameras in Elevator applications. ASTEL FTC SFTP CAT6 BC has Stranded Copper as a center conductor with HDPE Insulation. The cable features Dual Shielding and Dual Jacket with LSZH (Low Smoke Zero Halogen) outer jacket. It has two GI Steel Strength members on either side of the center conductor. All the cores are protected with Ultra Flexible PVC Jacket for repeated bending and traveling of elevators.
AED0.00

Details

ASTEL Flat Travelling Cables are designed and manufactured to Ultra flexibility demand of CCTV Cameras in Elevator applications. ASTEL FTC SFTP CAT6 BC has Stranded Copper as a center conductor with HDPE Insulation. The cable features Dual Shielding and Dual Jacket with LSZH (Low Smoke Zero Halogen) outer jacket. It has two GI Steel Strength members on either side of the center conductor. All the cores are protected with Ultra Flexible PVC Jacket for repeated bending and traveling of elevators.
 
Applications:
 
1) Elevator traveling cable for indoor and panoramic elevators.
2) IPC Cameras in Elevators.
3) Video Monitoring in Cranes.
4) Support All CAT6/Class E applications (10BaseT, 100Base-T, 1000Base-T, ISDN).
5) Maximum channel length 65m (transceiver to receiver

More Information

Technical specification

<address><strong>Technical Specifications:</strong></address><address> </address> <table style="width: 658px; border-color: black;" border="1"><colgroup><col /> <col /> <col /> </colgroup> <tbody> <tr> <td class="xl67"><strong><span style="font-family: verdana, geneva; font-size: small;">Model Product</span></strong></td> <td class="xl67"><strong><span style="font-family: verdana, geneva; font-size: small;">FTC SFTP CAT6 BC</span></strong></td> </tr> <tr> <td class="xl65"><strong><span style="font-family: verdana, geneva; font-size: small;">Cable Description</span></strong></td> <td class="xl63"> <p><span style="font-family: verdana, geneva; font-size: small;">Flat Flexible Elevator Cable </span><span style="font-family: verdana, geneva; font-size: small;">SFTP CAT6</span></p> </td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Conductor</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Bare Copper Stranded</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Conductor Structure</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">4 x 2 x 7*0.2</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Conductor Cross Section Area</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">0.22 mm2</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Insulation thickness</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">0.27 mm</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Foil Shielding 100% Coverage</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">YES</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">2nd Shielding</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Tinned Copper Braid</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Approximate Coverage</span></td> <td class="xl70"><span style="font-family: verdana, geneva; font-size: small;">60%</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">1st Jacket Dia</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">4.50 mm</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">1st Jacket Thickness</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">0.50 mm</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Overall Jacket</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Ultra Flex PVC</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Overall Jacket Size</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">19.0x9.60mm</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Minimum Jacket thickness in center</span></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> 9.60</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Maximum Jacket thickness at ends</span></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> 9.60</span></td> </tr> <tr> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;">Overall jacket Color</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;"> Grey</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Jacket Material</span></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> LSOH</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Insulation Resistance</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;"> ≥ 5000 MΩ.KM @ 20ºC</span></td> </tr> <tr> <td class="xl69"><strong><span style="font-family: verdana, geneva; font-size: small;">Strength Wires</span></strong></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Material</span></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;">GI Steel Wires </span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Construction</span></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;">Stranded and Compacted</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Conductor Size</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">2.50 mm2</span></td> </tr> <tr> <td class="xl69"><strong><span style="font-family: verdana, geneva; font-size: small;">Electric Specifications</span></strong></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Normal Operating Voltage</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">300VAC</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Maximum Operating Voltage</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">500VAC</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Conductor Resistance (max)</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">93.8 Ohms /KM</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Impedance</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">100±15 ohms</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Capacitance</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">43 pf/m</span></td> </tr> <tr> <td class="xl69"><strong><span style="font-family: verdana, geneva; font-size: small;">Fire Performance</span></strong></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Flame Propagation</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Complies with IEC / EN 60332-1-2</span></td> </tr> <tr> <td class="xl69"><strong><span style="font-family: verdana, geneva; font-size: small;">Mechanical Specifications</span></strong></td> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Free Suspension length</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Max 90 meter</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Lifting Height (tied with cable ties at specified intervals)</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Max 150 meter</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Operating Temp</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">-15°C to +70°C</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Sheath Tensile Strength before aging</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">≥ 10.0 N/mm2</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Sheath Elongation before aging</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">≥ 300%</span></td> </tr> <tr> <td class="xl69"><strong><span style="font-family: verdana, geneva; font-size: small;">Packing-1</span></strong></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">300m</span></td> </tr> <tr> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">Weight each coil</span></td> <td class="xl63"><span style="font-family: verdana, geneva; font-size: small;">42.50 Kg</span></td> </tr> <tr> <td class="xl65"><strong><span style="font-family: verdana, geneva; font-size: small;">Packing-2</span></strong></td> <td class="xl71"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl65"><span style="font-family: verdana, geneva; font-size: small;">Weight each Reel</span></td> <td class="xl71"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> </tbody> </table> <address> </address><address><strong><span style="font-family: verdana, geneva; font-size: small;">Installation Notes:</span></strong></address><address><span style="font-family: verdana, geneva; font-size: small;">Flexible cable should be tied with the cable rope by using high tensile cable ties at a gap of every 10 cm.</span><br /><span style="font-family: verdana, geneva; font-size: small;">When fixing the connectors, please give five loops of cable atleast with 20 cms diameter and then fix the metal shielded RJ45 Connector.</span><br /><span style="font-family: verdana, geneva; font-size: small;">Metal Shielded connector should be with Boot and can be directly plugged in the IPC.</span></address><address> </address><address><strong><span style="font-family: verdana, geneva; font-size: small;">Disclaimer</span></strong><br /><span style="font-family: verdana, geneva; font-size: small;">1. Astel Digicom Electronics reserves the right to change, modify specifications without prior notice.</span><br /><span style="font-family: verdana, geneva; font-size: small;">2. All pictures are for illustrative purposes only. Actual product may be different in color and size, which may appear in product specifications.</span><br /><span style="font-family: verdana, geneva; font-size: small;">3. Every effort is made to provide accurate information at the time of publishing, however Astel Digicom Electronics LLC is not responsible for</span><br /><span style="font-family: verdana, geneva; font-size: small;">any loss, directly or indirectly caused by any error in publishing.</span><br /><span style="font-family: verdana, geneva; font-size: small;">4. E&OE (Errors and Omissions are excepted)</span></address><address> </address><address> </address>