Technical specification
<address> <table style="width: 600px; border-color: #afcbe4; border-width: 1px; border-style: solid;" border="1"><colgroup><col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col span="2" /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col span="2" /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col /> <col span="2" /> <col /> <col /> <col /> <col /> </colgroup> <tbody> <tr> <td class="xl63" colspan="11"><strong><span style="font-family: verdana, geneva; font-size: small;">Model Product</span></strong></td> <td class="xl65" style="text-align: center;" colspan="12"><strong><span style="font-family: verdana, geneva; font-size: small;">CS5967BV</span></strong></td> <td class="xl65" style="text-align: center;" colspan="17"><strong><span style="font-family: verdana, geneva; font-size: small;">CS5995BV</span></strong></td> </tr> <tr> <td class="xl67" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Inner Conductor</span></td> <td class="xl69" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">Copper Clad Steel</span></td> <td class="xl69" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">Copper Clad Steel</span></td> </tr> <tr> <td class="xl71" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Braid Material</span></td> <td class="xl73" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">Al-Mg Alloy Wire</span></td> <td class="xl73" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">Al-Mg Alloy Wire</span></td> </tr> <tr> <td class="xl75" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Braid Coverage</span></td> <td class="xl77" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">67% Coverage</span></td> <td class="xl77" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">95% Coverage</span></td> </tr> <tr> <td class="xl79" colspan="11"><strong><span style="font-family: verdana, geneva; font-size: small;">Construction</span></strong></td> <td class="xl80" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td class="xl80" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl67" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Center Conductor Diameter</span></td> <td class="xl69" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">0.81 mm</span></td> <td class="xl69" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">0.81 mm</span></td> </tr> <tr> <td class="xl83" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Foam PE Dialetric</span></td> <td class="xl85" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">3.66 mm</span></td> <td class="xl85" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">3.66 mm</span></td> </tr> <tr> <td class="xl75" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Sealed AP Tape</span></td> <td class="xl77" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">3.82 mm</span></td> <td class="xl77" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">3.82 mm</span></td> </tr> <tr> <td class="xl71" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Aluminum Braiding</span></td> <td class="xl73" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">4.45 mm</span></td> <td class="xl73" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">4.45 mm</span></td> </tr> <tr> <td class="xl87" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Alumin<span class="font5">um Foil</span></span></td> <td class="xl69" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">NA</span></td> <td class="xl69" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">NA</span></td> </tr> <tr> <td class="xl88" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Jacket Material</span></td> <td class="xl85" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">PVC</span></td> <td class="xl85" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">PVC</span></td> </tr> <tr> <td class="xl67" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Jacket</span></td> <td class="xl69" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">6.10 mm</span></td> <td class="xl69" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">6.10 mm</span></td> </tr> <tr> <td class="xl71" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Jelly (For Corrosion Protection)</span></td> <td class="xl73" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">NO</span></td> <td class="xl73" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">NO</span></td> </tr> <tr> <td class="xl90" colspan="11"><strong><span style="font-family: verdana, geneva; font-size: small;">Electric Specifications</span></strong></td> <td class="xl91" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td class="xl91" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl71" colspan="11"><strong><span style="font-family: verdana, geneva; font-size: small;">Nominal DC Resistance @ 20 deg C</span></strong></td> <td class="xl80" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td class="xl80" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl67" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Inner Conductor</span></td> <td class="xl69" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">160 ohms/KM</span></td> <td class="xl69" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">160 ohms/KM</span></td> </tr> <tr> <td class="xl71" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Outer Conductor</span></td> <td class="xl73" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">34 ohms/KM</span></td> <td class="xl73" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">22 ohms/KM</span></td> </tr> <tr> <td class="xl75" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Nominal Capacitance</span></td> <td class="xl77" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">53.0 pf</span></td> <td class="xl77" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">53.0 pf</span></td> </tr> <tr> <td class="xl71" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Impedance</span></td> <td class="xl73" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">75±3 ohms</span></td> <td class="xl73" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">75±3 ohms</span></td> </tr> <tr> <td class="xl75" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">Propagation Velocity Ratio</span></td> <td class="xl77" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">82%</span></td> <td class="xl77" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">82%</span></td> </tr> <tr> <td class="xl79" colspan="11"><strong><span style="font-family: verdana, geneva; font-size: small;">Packing</span></strong></td> <td class="xl80" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> <td class="xl80" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;"> </span></td> </tr> <tr> <td class="xl75" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">"100Y Reel-CTN Size QTY-6 pcs/CTN"</span></td> <td class="xl77" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">28x28x58 cms</span></td> <td class="xl77" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">28x28x58 cms</span></td> </tr> <tr> <td class="xl71" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">100Y Reel-CTN-Weight</span></td> <td class="xl73" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">18 kgs</span></td> <td class="xl73" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">20 kgs</span></td> </tr> <tr> <td class="xl75" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">305M Reel-Size</span></td> <td class="xl77" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">30x30x30</span></td> <td class="xl77" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">30x30x30</span></td> </tr> <tr> <td class="xl94" colspan="11"><span style="font-family: verdana, geneva; font-size: small;">305M Reel-Weight</span></td> <td class="xl96" style="text-align: center;" colspan="12"><span style="font-family: verdana, geneva; font-size: small;">11 kgs</span></td> <td class="xl96" style="text-align: center;" colspan="17"><span style="font-family: verdana, geneva; font-size: small;">11 kgs</span></td> </tr> </tbody> </table> </address><address> </address><address> </address><address> </address><address><span style="font-family: verdana,geneva; font-size: x-small; color: #ff0000;">Disclaimer</span><br /><span style="font-family: verdana,geneva; font-size: x-small; color: #000000;">1. Astel Digicom Electronics reserves the right to change, modify specifications without prior notice.</span><br /><span style="font-family: verdana,geneva; font-size: x-small; color: #000000;">2. All pictures are for illustrative purposes only. Actual product may be different in color and size, which may appear in product specifications.</span><br /><span style="font-family: verdana,geneva; font-size: x-small; color: #000000;">3. Every effort is made to provide accurate information at the time of publishing, however Astel Digicom Electronics LLC is not responsible for</span><br /><span style="font-family: verdana,geneva; font-size: x-small; color: #000000;">any loss, directly or indirectly caused by any error in publishing.</span><br /><span style="font-family: verdana,geneva; font-size: x-small; color: #000000;">4. E&OE (Errors and Omissions are excepted)</span></address>